| services | audio/video | car extras | dynamometers |
|
|
ordering | downloads | contact us | links |
|
High Spec Lead Acid Battery Conditioner.
This unit will condition and keep charged all 12V vehicle batteries. Its high output means that it rapidly recovers discharged units, and easily powers modern vehicles' alarms radios etc, most similar units have inadequate current output.
Standard 12V Version; 24V for Marine use also available.
|
|
|
||
| Input voltage: | 190 - 264 VAC / 240-360 VDC | ||
| Charging voltage |
14,7 V ± 0,1 V cycle, 13,8 V ± 0,1 V standby |
||
| Max output power: | 40 W | ||
|
Load regulation (0,2-2,4 A load and 230 VAC mains): |
< 200 mV | ||
|
Line regulation (190-264 VAC mains at full load): |
< 20 mV | ||
| Switch frequency: | 45 kHz | ||
|
Leakage current from battery when mains switched off: |
< 100 uA | ||
| Temperature range: | -10°C - +40 °C | ||
| Ripple: | < 20 mV p-p 40 kHz and 100 Hz | ||
| Efficiency (at full load): | > 81 % | ||
| Current limiting: | 2,7 A ± 0,3 A | ||
| Insulation class: | II | ||
| Electrical safety standard: |
EN 60335-1, EN 60335-2-29 EN 60065, EN 60950 |
||
| EMC standards | |||
|
|
EN 50081-1 | ||
|
|
EN 50082-1 | ||
| Indicators | |||
|
|
2.7 A | ||
|
|
14.7 V | ||
|
|
13.8 V | ||
| Timer: | 2 h ± 30min. | ||
| Output terminals | |||
|
|
|||
|
Dimensions without plug (LxWxH): |
100 x 51 x 63 mm | ||
| Weight: | 0.25 kg | ||
|
Some technical specifications may differ for other voltage versions. The timer is also avialable with other values. |
|||

|
|||||||||||||||||
© GAA 2003-