services audio/video car extras dynamometers
ordering downloads contact us links

 

 

 

 Technical specifications 

( 12 V version)
 
Input voltage: 190 - 264 VAC / 240-360 VDC 
Charging voltage 14,7 V ± 0,1 V cycle,
13,8 V ± 0,1 V standby 
Max output power: 40 W 
Load regulation
(0,2-2,4 A load and 230 VAC mains):
< 200 mV 
Line regulation
(190-264 VAC mains at full load):
< 20 mV 
Switch frequency: 45 kHz 
Leakage current from battery
when mains switched off:
< 100 uA  
Temperature range: -10°C - +40 °C 
Ripple: < 20 mV p-p 40 kHz and 100 Hz  
Efficiency (at full load): > 81 % 
Current limiting: 2,7 A ± 0,3 A 
Insulation class: II 
Electrical safety standard: EN 60335-1, EN 60335-2-29
EN 60065, EN 60950 
EMC standards  
  • Emission:
  • EN 50081-1 
  • Immunity:
  • EN 50082-1 
    Indicators  
  • Red (constant current):
  • 2.7 A 
  • Yellow (constant voltage timer):
  • 14.7 V 
  • Green (constant voltage standby):
  • 13.8 V 
    Timer: 2 h ± 30min. 
    Output terminals  
  • Cord with crocodile clips
  •    
    Dimensions without plug
    (LxWxH):
    100 x 51 x 63 mm 
    Weight: 0.25 kg 

    Some technical specifications may differ for other voltage versions. The timer is also avialable with other values. 


    Input (VAC) Output (VDC) Current limit (A) Max. output power (W)
    Cycle Standby
    90-130 14,7 ± 0,1 13,8 ± 0,1 2,7 ± 0,3 40
    190-264 14,7 ± 0,1 13,8 ± 0,1 2,7 ± 0,3 40


    © GAA 2003-